Electrical Specifications -

Parameter Symbol Min Typical Max Unit
Operating Temperature TO 25
AWG252 Clock Frequency fCK 0.5 > 2  GHz 
AWG452 Clock Frequency fCK 1 > 4  GHz 
Clock Input Power PCK 2 3 4 dBm
Output Level Vout -635   0 mV
Output Power Pout -4   0 dBm
Output Phase Noise Nφ     -130 dBc/Hz
Clock Port Return Loss RLCK   15   dB
Output Port Return Loss RLRF   15   dB
AWG252
Power Supply (in lieu of single +12V supply)
-5V -4.5 -5 -5.5 V
I-5   915   mA
+1.8V +1.7 +1.8 +1.9 V
I+1.8  1600* mA
+3.3V +3 +3.3 +3.5 V
I+3.3   195   mA
+5V +4.5 +5 +5.5 V
I+5   205   mA
AWG252
Power Supply
V+12 +12 V
I+12  0.9 1.1 1.3  A
AWG452
Power Supply
V+12 +12 V
I+12  0.9 1.1 1.3  A
AWG801
Power Supply
V+12 +12 V
I+12 2 2.8 3 A


* Current for the 1.8V supply varies with clock frequency. At 2 GHz clock frequency, the 1.8V supply current is near 1.6A for the AWG252.