Hardware Setup-
» Connect your spectrum analyzer to the OUT horizontal SMA connector.
            
            » Set the DDS clock source to the desired frequency with 3 dBm power. Connect the clock to the 
            DDSCK vertical SMA connector.
        
            
            » Set the carrier frequency clock source to the desired frequency with 6 dBm power. Connect the clock to the 
            LO horizontal SMA connector.
        
            
            » Connect the DSM board to your PC with the USB A-B cable.
        
            
            » Plug the AC adapter to a wall outlet and connect the power jack to the connector on the board.
        
            
            » If you have done everything correctly, you should see the built-in waveform output on your
            spectrum analyzer.